Primus Cable CAT5E Outdoor, Shielded, Aerial w/ Messenger, 1000ft Spool, Black, C5CMXSM-3203
Primus CableCAT5E 350MHz Outdoor Aerial Shielded Bulk Cable Features:
- High-Performance Data Communications Cable
- This cable is Cat5E Outdoor CABLE UV Rated for outdoor use.
- Suitable for 350MHz High-Speed Data Applications, Gigabit Ethernet, Fast Ethernet and 155Mbps TP-PMD/CDDI
- Designed for Outdoor Installations UV Jacket (CMX) (UV)
- Category-5E Foil Shielded Twisted Pair (FTP) Cable
- 4-Pair – Easily Identified Color-Striped Pairs
- 24 AWG Solid Bare Copper Conductors
- Excellent Attenuation and Crosstalk Characteristics
- Breaking Tension of the Messenger: 1370 Mpa
- Maximum Hang Distance: 70 Meters
- Exceeds EIA/TIA 568 B.2-1
- UL/cUL or ETL Listed
- Sequential Length Markings on Jacket
- Supplied in 1000´ Wooden Spool / Pull Box
CAT5E Outdoor Aerial Shielded Cable:
Galvanized Steel Messenger Wire provides ideal support for aerial cables applications to reduce cable sag over set hang points. Cat5e Shielded Outdoor CMX / Outside Plant (OSP) Aerial Cable with messenger cable and UV protected jackets. This cable is Shielded with Galvanized Steel Wire and is ideal for outdoors network installations.
Aerial Messenger, Shielded Enhanced Cat 5e cable featuring 24 AWG solid bare copper conductors. This cable is verified by ETL to be type CMX. The wires are 24 AWG in size and are made of solid bare (pure) copper conductors. All 4 pairs are easily identified by color stripes. This cable is shielded Foil with UV Resistant PE jacket material.
CAT5E Cable Options
Solid Wire: Also called solid-core or single-strand wire, consists of one piece of metal wire. Stranded wire is composed of a bundle of small-gauge wires to make a larger conductor and more flexible than solid wire. Solid wire is generally used for in-wall wiring where there is little need for flexibility in the wire.
CMR: The 'R' in CMR is for 'Riser'. Riser type cables are engineered to prevent the spread of fire from floor to floor and are suitable for vertical shaft applications.
CMP: The 'P' in CMP is for Plenum. Cables meeting type CMP requirements are suitable for installation in ducts and plenums without the use of conduit. These cables are designed for fire resistance and low-smoke and toxin producing characteristics.
CMX: The 'X' in CMX is for Outside Plant. Cables meeting type CMX requirements are suitable for installation in outdoor applications where exposed to the elements.
CM/CMH/CMG: CM is used for general building wiring such as residential house. CM cables are used in areas other than plenums and risers.
- WM #:
- 112511955
- Outdoor Use:
- Yes
- Features:
- Shielded